Custom Pulse Transformers

Our team of engineers can design a pulse transformer to , to and to have a low coupling capacitance between the primary and secondary for purposes of protecting against transients. QTE designs pulse transformers with a focus on duty cycle and voltage time integral (pulse integral).

  • minimize distortion of the pulse shape,
  • have low leakage of inductance,
  • have a low coupling capacitance between the primary and secondary for purposes of protecting against transients.
Contact a sales representative Specifying your transformer
Power Rating 50VA up to 8MW
Voltages Up to 50kVrms
Optional features Pulse width
Pulse repetition rate
Reset current
Enclosure
Water-cooled transformer

Examples

Custom Pulse Transformer Custom Pulse Transformer
10mHy Pulse Transformer 10mHy Pulse Transformer
7.2MW Pulse Transformer 7.2MW Pulse Transformer

15kVA Transformers

Custom Pulse Transformer
2uS pulse transformers for use in a medical linear accelerator.
Pulse Width 2uS
Pulse Voltage 360PPS
Primary Voltage 340V
Operating Current 3.5A
Secondary Voltage 2400V
Secondary Current 215A peak
Dielectric Withstanding Voltage Primary 1kVDC
Dielectric Withstanding Voltage Primary 10kVDC

10mHy Pulse Transformer

10mHy Pulse Transformer
10mHy pulse bias isolation inductor used in a medical linear accelerator.
Pulse Width 4uS
Pulse Repetition Rate 360PPS
Operating Current 3.5A

7.2MW Pulse Transformer

7.2MW Pulse Transformer
7.2MW, 450uS pulse transformer for use in an industrial linear accelerator for food sterilization.
Pulse Width 450uS
Pulse Voltage 60PPS Max
Primary Voltage 8.5kV peak
340V
Primary Current 850A peak
Secondary Voltage 34kV peak
Secondary Current 215A peak
Average Current 250kW
Reset Current 0.5A minimum through secondary winding
Features Water cooled primary windings
Housed in NEMA1 enclosure