Custom Transformers

Transform power, your way

Partner with QT&E for reliable, high-performance transformers tailored to your exact specifications—built for efficiency, durability, and your industry's unique needs. Request a quote today to get started.

A set of custom transformers designed and manufactured by Quality Transformer & Electronics.

Configurable Options in our Custom Transformers

Electrical

Power Rating

Specify the required power by calculating secondary voltage multiplied by current. ex. 10 kVA. QT&E supports power ranges from:

1 VA - 1 kVA
1 kVA - 100 kVA
100 kVA - 2 MVA

Frequency

Define the operating frequency of your system (e.g., 50 Hz, 60 Hz, or custom). ex. 60 Hz. QT&E supports frequencies from:

50 Hz or 60 Hz
400 Hz - 20 kHz

Phases

Choose between single-phase or three-phase configurations to match your application requirements; QT&E designs for both types. ex. 3PH.

Single-phase
Three-phase
Two-phase

Inputs & Outputs

Indicate the number, voltage, and current ratings for primary and secondary windings; QT&E accommodates a wide range of configurations and load profiles. ex. Input: 480V, Output: 120/240V split-phase.

1 V up to 600 V (up to 1.5 MVA)
600V up to 240 kV
(current or power rating needed along with voltage)

Isolation

Specify isolation requirements to ensure safety and signal integrity. ex. 4 kV isolation voltage. QT&E supports:

5 kV standard
5 kV up to 200 kV (custom)

Inrush

Detail any limitations on inrush current for your application; QT&E designs transformers with low inrush or soft-start options. ex. 5x full-load current for 10 milliseconds

Impedance

State the desired impedance to control voltage regulation and fault currents; QT&E provides custom designs to meet specific impedance values. ex. 4% (typical range: 2% to 8%)

K-rating

Specify a K-factor to handle harmonic loads. ex. K-13 (designed for harmonic loads in data centers). QT&E supports:

K-1 (standard)
K-4, K-13, K-20 for data centers and other sensitive applications

Short-circuit strength

Define the fault tolerance requirements; QT&E designs transformers to withstand high fault currents up to 100 kA. ex. Withstands 25 kA for 1 second

Efficiency Standard

Choose an efficiency standard (e.g., DOE 2016, NEMA Premium); QT&E ensures compliance with the highest energy efficiency benchmarks. ex. NEMA TP-1 or DOE 2016 Compliant

Noise suppression

Indicate the need for minimizing audible or electrical noise; QT&E incorporates low-noise laminations and shielding for sensitive environments. ex. 40 dB attenuation at 1 kHz

Ground loop elimination

State requirements for reducing ground loops in your system; QT&E designs with specialized grounding and isolation techniques. ex. Floating secondary with ground shield

Shielding

Specify electromagnetic or electrostatic shielding to prevent interference; QT&E offers designs with custom shielding options. ex. Faraday shield with 90% attenuation

Low Leakage Current

Define acceptable leakage current levels for safety or regulatory compliance; QT&E produces designs with minimized leakage current. ex. < 300 μA

Phase Angle Control

Indicate if phase-angle adjustments are needed for precise control; QT&E designs transformers optimized for phase control applications. ex. ±5° phase shift between primary and secondary

Harmonic Mitigation

Specify harmonic reduction needs to improve power quality; QT&E provides designs with specialized cores and K-rated transformers. ex. Reduces THD to <5%

Load Balancing

Describe requirements for balancing loads across phases; QT&E offers solutions to improve phase balance in single- or three-phase systems. ex. ±3% balance between phases

Voltage Regulation

Indicate tolerance for voltage fluctuations; QT&E ensures precise regulation through advanced winding and core designs. ex. ±1% under varying loads

DC Ripple Management

Define your tolerance for DC ripple in rectified outputs; QT&E designs for low ripple with advanced filtering. ex. Ripple voltage <1% of DC output

Pulse Shape Fidelity

Specify the need for high-fidelity pulse shaping in applications like power supplies or amplifiers; QT&E delivers precise waveform reproduction. ex. Rise time <50 nanoseconds with minimal overshoot

Fast Rise Times

Detail the requirement for rapid voltage or current transitions; QT&E provides solutions optimized for high-speed applications. ex. 10 microseconds from 10% to 90% of final value

Mechanical

Temperature Rise

Specify the allowable temperature rise above ambient for your application (measured in °C), typically based on insulation class or operational needs. ex. 80°C (standard for Class B).

Dimensions

Define the physical size constraints (height, width, depth) to fit your installation space. ex. H: 24 in, W: 18 in, D: 12 in

Terminal Configuration

Specify the type of terminals required, including material (e.g., copper or aluminum), plating, and configuration (e.g., screw, stud, or busbar) based on conductivity and installation needs. ex. Tin-plated copper busbars with 3/8-inch studs. Options include:

Copper buss bar
Silicon bronze hardware
Terminal strip
Ring-lug compatibility
Touch-safe configurations
Lexan covers

Enclosure

Indicate the required enclosure type based on environmental conditions, such as indoor, outdoor, or hazardous locations. ex. NEMA 1 (indoor use). Options include:

NEMA 1: Standard
NEMA 2
NEMA 3 + 3R: Protection from falling water.
NEMA 4 + 4X:
Water proof, fully enclosed.
NEMA 6

Circuit Protection

Specify integrated circuit protection needs, such as fuses or breakers, for overload and fault conditions. ex. Primary & Secondary circuit breakers. Options include:

Circuit breakers
Fuses

Seismic Kits

Indicate if seismic bracing is needed to meet building codes in earthquake-prone areas. ex. Designed for Zone 4 seismic compliance

Emergency Off and Safety

Define any emergency stop or safety requirements, such as accessible shutoff switches or interlocks. ex. Red emergency-off push button on front panel

Cooling Method

Specify the cooling method required, such as natural convection, forced air, or liquid cooling, based on operating environment and power density. ex. Forced air cooling with fans or Liquid-cooled system

Voltage Tap Changers

Specify if adjustable voltage taps are needed to fine-tune output voltage under varying input conditions. ex. voltage tap changer for ±5% taps on primary winding in 2.5% increments

Notifications

Define any notification features required, such as indicator lights, alarms, or digital displays for system status. ex. Green (Power On), Red (Fault) indicator lights with an audible alarm for overload

Examples of Custom Transformer Applications

1,600 A Zigzag Transformer

Grounding Transformer

1,600 A Zigzag Transformer

3-Phase · 60Hz · 400 Vrms L-L · 1,600 Arms neutral current · 0.0006 Ohms
225 KVA General Purpose Transformer

Low Voltage Transformer

225 kVA Transformer

3-Phase · 50/60Hz · 480Vrms delta in · 340 - 520Vrms wye out · NEMA1 enclosure w/doors
28 KVA Isolation Transformer

Isolation Transformer

14.28 kVA Transformer

1-Phase · 60Hz · 240/480Vrms in · 4 secondaries · 1,500Vrms primary isolation · 5kVDC secondary isolation
7.2 kVA Noise Cut Transformer

Noise Cut Transformer

7.2 kVA Noise Cut Transformer

3-Phase · 50/60Hz · 208 Vrms in · 208 Vrms @ 30 Arms and 120 Vrms @ 6 Arms out · Casters