Noise Cut Transformers

Noise Cut Transformers for Superior Power Quality and Reduced Interference

High-performance noise cut transformers designed to minimize electromagnetic interference, eliminate harmonics, and provide clean, stable power for sensitive equipment in industrial, medical, and commercial applications.

Noise Cut Transformer hero image

Configurable Options in our Noise Cut Transformers

Electrical

Power Rating

Specify the required power by calculating secondary voltage multiplied by current. ex. 10 kVA. QT&E supports power ranges from:

1 VA - 1 kVA
1 kVA - 150 kVA

Frequency

Define the operating frequency of your system (e.g., 50 Hz, 60 Hz, or custom). ex. 60 Hz. QT&E supports frequencies from:

50 Hz or 60 Hz

Phases

Choose between single-phase or three-phase configurations to match your application requirements; QT&E designs for both types. ex. 3PH.

Single-phase
Three-phase

Inputs & Outputs

Indicate the number, voltage, and current ratings for primary and secondary windings; QT&E accommodates a wide range of configurations and load profiles. ex. Input: 480V, Output: 120/240V split-phase.

1 V up to 600 V (up to 150 kVA)

Isolation

Specify isolation requirements to ensure safety and signal integrity. ex. 4 kV isolation voltage. QT&E supports:

5 kV standard
5 kV up to 200 kV (custom)

Noise Attenuation (Common)

Reduces interference where identical noise appears on both lines relative to ground, typically using shields or balanced windings. ex. 30 dB common-mode noise attenuation at 1 kHz.

Noise Attenuation (Differential)

Minimizes noise that exists as a voltage difference between two lines, often achieved through precision filtering or core designs. ex. Example:20 dB differential-mode noise attenuation from 10 kHz to 100 kHz.

Impedance

State the desired impedance to control voltage regulation and fault currents; QT&E provides custom designs to meet specific impedance values. ex. 4% (typical range: 2% to 8%)

Noise suppression

Indicate the need for minimizing audible or electrical noise; QT&E incorporates low-noise laminations and shielding for sensitive environments. ex. 40 dB attenuation at 1 kHz

Electrostatic shielding

Specify electromagnetic or electrostatic shielding to prevent interference; QT&E offers designs with custom shielding options. ex. Faraday shield with 90% attenuation

Harmonic Mitigation

Specify harmonic reduction needs to improve power quality; QT&E provides designs with specialized cores and K-rated transformers. ex. Reduces THD to <5%

Ground loop elimination

State requirements for reducing ground loops in your system; QT&E designs with specialized grounding and isolation techniques. ex. Floating secondary with ground shield

Low Leakage Current

Define acceptable leakage current levels for safety or regulatory compliance; QT&E produces designs with minimized leakage current. ex. < 300 μA

Mechanical

Temperature Rise

Specify the allowable temperature rise above ambient for your application (measured in °C), typically based on insulation class or operational needs. ex. 80°C (standard for Class B).

Dimensions

Define the physical size constraints (height, width, depth) to fit your installation space. ex. H: 24 in, W: 18 in, D: 12 in

Enclosure

Indicate the required enclosure type based on environmental conditions, such as indoor, outdoor, or hazardous locations. ex. NEMA 1 (indoor use). Options include:

NEMA 1: Standard
NEMA 2
NEMA 3 + 3R: Protection from falling water.
NEMA 4 + 4X:
Water proof, fully enclosed.
NEMA 6

Circuit Protection

Specify integrated circuit protection needs, such as fuses or breakers, for overload and fault conditions. ex. Primary & Secondary circuit breakers. Options include:

Circuit breakers
Fuses

Seismic Kits

Indicate if seismic bracing is needed to meet building codes in earthquake-prone areas. ex. Designed for Zone 4 seismic compliance

Emergency Off and Safety

Define any emergency stop or safety requirements, such as accessible shutoff switches or interlocks. ex. Red emergency-off push button on front panel

Notifications

Define any notification features required, such as indicator lights, alarms, or digital displays for system status. ex. Green (Power On), Red (Fault) indicator lights with an audible alarm for overload

Examples of Noise Cut Transformer Applications

16.8 kVA noise cut transformer

16.8 kVA Noise Cut Transformer

3-Phase · 50/60Hz · 208 Vrms in · 220 Vrms @ 7 Arms out · Primary/Secondary circuit breakers · NEMA4 enclosure · NRTL to UL 1561, CE Mark
10.8 kVA noise cut assembly

10.8 kVA Noise Cut Assembly

3-Phase · 50/60Hz · 208 Vrms in · 208/120Vrms @ 30 Arms out · Line filter · Seismic floor mounts · NRTL to UL 1561, 508A, CE Mark
7.2 kVA Noise Cut Transformer

7.2 kVA Noise Cut Transformer

3-Phase · 50/60Hz · 208 Vrms in · 208 Vrms @ 30 Arms out 1 · 120 Vrms @ 6 Arms out 2 · Casters · NRTL to UL 1561, 508A, CE Mark