SCR Assemblies

SCR Assemblies for High-Performance Power Control

Reliable and robust SCR assemblies designed for efficient and precise power management in industrial, commercial, and specialized applications, including heating, motor control, and rectification.

SCR assemblies by Quality Transformer & Electronics.

Configurable Options in our SCR Assemblies

Electrical

Power Rating

Specify the required power by calculating secondary voltage multiplied by current. ex. 10 kVA. QT&E supports power ranges from:

1 VA - 1 kVA
1 kVA - 500 kVA

Frequency

Define the operating frequency of your system (e.g., 50 Hz, 60 Hz, or custom). ex. 60 Hz. QT&E supports frequencies from:

50 Hz or 60 Hz

Inputs & Outputs

Indicate the number, voltage, and current ratings for primary and secondary windings; QT&E accommodates a wide range of configurations and load profiles. ex. Input: 480V, Output: 120/240V split-phase.

1 V up to 600 V

Isolation

Specify isolation requirements to ensure safety and signal integrity. ex. 4 kV isolation voltage. QT&E supports:

5 kV standard
5 kV up to 200 kV (custom)

Impedance

State the desired impedance to control voltage regulation and fault currents; QT&E provides custom designs to meet specific impedance values. ex. 4% (typical range: 2% to 8%)

K-rating

Specify a K-factor to handle harmonic loads. ex. K-13 (designed for harmonic loads in data centers). QT&E supports:

K-1 (standard)
K-4, K-13, K-20 for data centers and other sensitive applications

Voltage Regulation

Indicate tolerance for voltage fluctuations; QT&E ensures precise regulation through advanced winding and core designs. ex. ±1% under varying loads

Current limiting

Specify the maximum allowable current to safeguard the SCR assembly and connected equipment from overcurrent conditions. QT&E provides solutions with integrated current-limiting functionality. ex. 150A peak with automatic recovery.

Power factor correction

Define the power factor improvement needed to optimize energy efficiency and reduce reactive power in your system. ex. ≥ 0.98 for a 10 kW system.

Mechanical

Temperature Rise

Specify the allowable temperature rise above ambient for your application (measured in °C), typically based on insulation class or operational needs. ex. 80°C (standard for Class B).

Dimensions

Define the physical size constraints (height, width, depth) to fit your installation space. ex. H: 24 in, W: 18 in, D: 12 in

Enclosure

Indicate the required enclosure type based on environmental conditions, such as indoor, outdoor, or hazardous locations. ex. NEMA 1 (indoor use). Options include:

NEMA 1: Standard
NEMA 2
NEMA 3 + 3R: Protection from falling water.
NEMA 4 + 4X:
Water proof, fully enclosed.
NEMA 6

Circuit Protection

Specify integrated circuit protection needs, such as fuses or breakers, for overload and fault conditions. ex. Primary & Secondary circuit breakers. Options include:

Circuit breakers
Fuses

Programmable Control

Many SCR assemblies allow remote or programmable control for voltage and current settings, ideal for automated or precision applications.

EMI/RFI Suppression

Advanced designs include filters to minimize electromagnetic interference and ensure compatibility with sensitive electronic equipment.

Examples of SCR Assemblies Applications

26 kVA SCR assembly

26 kVA SCR Assembly

380/400/415/480 Vrms in · 3x secondaries out · SCR controlled · NRTL to UL 1561, CE Mark
155 kVA SCR Assembly

144 kVA SCR Assembly

3-Phase · 60Hz · 480 Vrms L-L · 300 VDC @ 480 ADC · Forced air cooling, soft start · NRTL to UL 1561
5.2 kVA SCR Assembly

5.2 kVA SCR Assembly

1-Phase · 60Hz · 208/220/240 Vrms in · 0-10/20/30 VDC @ 0-130 ADC · SCR controlled, firing board · NRTL to UL 1561, 508A