Electrical
Power Rating
Specify the required power by calculating secondary voltage multiplied by current. ex. 10 kVA. QT&E supports power ranges from:
1 VA - 1 kVA
1 kVA - 100 kVA
100 kVA - 1.5 MVA
Frequency
Define the operating frequency of your system (e.g., 50 Hz, 60 Hz, or custom). ex. 60 Hz. QT&E supports frequencies from:
50 Hz or 60 Hz
400 Hz up to 20 kHz
Phases
Choose between single-phase or three-phase configurations to match your application requirements; QT&E designs for both types. ex. 3PH.
Single-phase
Three-phase
Inputs & Outputs
Indicate the number, voltage, and current ratings for primary and secondary windings; QT&E accommodates a wide range of configurations and load profiles. ex. Input: 480V, Output: 120/240V split-phase.
1 V up to 600 V (up to 1.5 MVA)
Pulse
Specify the required pulse configuration for your application, determined by the desired level of harmonic reduction and power conversion efficiency. ex. 12-pulse. QT&E supports:
6
12
24
Impedance
State the desired impedance to control voltage regulation and fault currents; QT&E provides custom designs to meet specific impedance values. ex. 4% (typical range: 2% to 8%)
K-rating
Specify a K-factor to handle harmonic loads. ex. K-13 (designed for harmonic loads in data centers). QT&E supports:
K-1 (standard)
K-4, K-13, K-20 for data centers and other sensitive applications
Voltage Regulation
Indicate tolerance for voltage fluctuations; QT&E ensures precise regulation through advanced winding and core designs. ex. ±1% under varying loads
DC Ripple Management
Define your tolerance for DC ripple in rectified outputs; QT&E designs for low ripple with advanced filtering. ex. Ripple voltage <1% of DC output
Mechanical
Temperature Rise
Specify the allowable temperature rise above ambient for your application (measured in °C), typically based on insulation class or operational needs. ex. 80°C (standard for Class B).
Dimensions
Define the physical size constraints (height, width, depth) to fit your installation space. ex. H: 24 in, W: 18 in, D: 12 in
Enclosure
Indicate the required enclosure type based on environmental conditions, such as indoor, outdoor, or hazardous locations. ex. NEMA 1 (indoor use). Options include:
NEMA 1: Standard
NEMA 2
NEMA 3 + 3R: Protection from falling water.
NEMA 4 + 4X: Water proof, fully enclosed.
NEMA 6
Circuit Protection
Specify integrated circuit protection needs, such as fuses or breakers, for overload and fault conditions. ex. Primary & Secondary circuit breakers. Options include:
Circuit breakers
Fuses
Seismic Kits
Indicate if seismic bracing is needed to meet building codes in earthquake-prone areas. ex. Designed for Zone 4 seismic compliance
Cooling Method
Specify the cooling method required, such as natural convection, forced air, or liquid cooling, based on operating environment and power density. ex. Forced air cooling with fans or Liquid-cooled system